GPR-2500 AIS % OXYGEN TRANSMITTER
Xuất sứ: USA
Nhà cung cấp: ANS Vietnam
Hãng sản xuất: Aii1
Ứng dụng sản phẩm: Natural Gas Products
Liên hệ tư vấn
ATEX and cUL certified analyzer measures O2 concentrations from 0.05% to 100%. Features certification to ATEX Directive 94/9/EC and cUL designed exclusively for Natural Gas applications. This analyzer features an advanced galvanic oxygen sensor, a 36 month operating life, menu driven controls, two (2) field selectable alarm set points, and a stainless steel sample system. Pictured with the optional A-3393 modular sample system designed to remove moderate amounts of free liquids and H2S from natural gas streams
Accuracy: | < 2% of FS range under constant conditions | Analysis: | 0-10 PPM, 0-100 PPM, 0-1000 PPM, 0-1%, 0-25% FS ranges; auto-ranging or manually lock on single range |
Application: | Oxygen analysis in inert, hydrocarbon, helium, hydrogen, mixed and acid (CO2) gas streams |
Approvals: | EC TYPE EXAMINATION CERTIFICATE: INERIS 08ATEX0036 II 2 G Ex d [ib] ib IIB T4 Tamb-20⁰C to +50⁰C |
Area Classification: | Meets the recognized intrinsic safety standards for use in Class 1, Division 1, Group C, D hazardous |
Alarms: | Two user configurable alarms: magnetic coil relays rated 3A at 100 VAC, field programmable alarm time delays, alarm bypass for calibration and system fail alarm |
Calibration: | Air or certified span gas of O2balance N2approximating 80% of range above analysis range recommended |
Compensation: | Barometric pressure and temperature |
Connections: | 1/8″ compression tube fittings | Controls: | Water resistant keypad; menu driven range selection, calibration and system functions |
Display: | Graphical LCD 2.75” x 1.375”; resolution 0.01 PPM; displays real time ambient temperature and pressure |
Enclosure: | Aluminum ex-proof, fiberglass NEMA 4X, 16x9x6”, 20 lbs. |
Flow Sensitivity: | None between 0.5-5 SCFH, 1-2 SCFH recommended | Linearity: | ±1% of full scale |
Pressure: | Inlet – regulate to 5-30 psig to deliver 1-2 SCFH flow to transmitter; vent – atmospheric |
Power: | 12-24 VDC (suitable for solar power systems) or 100/230 VAC |
Response Time: | 90% of final reading in 10 seconds | Sample System: | Sample flow meter |
Sensitivity: | < 0.5% of FS range | Sensor Model: | XLT-12-333 for gases containing > 0.5% CO2 |
Sensor Life: | 24 months at 25ºC and 1 atm. | Signal Output: | 4-20mA |
Operating Range: | Recommended -20ºto 45ºC (XLT sensor) -10 ºC to 45ºC (GPR sensor) |
Warranty: | 12 months analyzer; 12 months sensor |
Wetted Parts: | Stainless steel |