GPR-2500 % OXYGEN TRANSMITTER
Xuất sứ: USA
Nhà cung cấp: ANS Vietnam
Hãng sản xuất: Aii1
Ứng dụng sản phẩm: Natural Gas Products
Liên hệ tư vấn
ATEX approved Intrinsically safe 2-wire loop powered %O2 transmitter for measuring %O2 concentrations in a gas mixture. Transmitter is a two wire loop powered and features certification to ATEX Directive 94/9/EC with intrinsic safety barrier, an advanced galvanic type % oxygen sensor, a 32 month operating sensor life, menu driven controls, and a stainless steel sample system,
Certifications:
ATEX Directive 94/9/ EC
Ex ia IIB T4 Gb
Tamb -10oC to 45oC
Accuracy: | < 2% of FS range under constant conditions | Analysis: | 0-1%, 0-5%, 0-10%, 0-25% FS ranges; |
Application: | Oxygen analysis in inert, hydrocarbon, hydrogen, mixed and acid (CO2) gas streams | Approvals: | INERIS 08ATEX0036 Ex ia IIB Gb T4 |
Area Classification: | Class 1, Division 1, Group C, D hazardous | Calibration: | Air or certified span gas of O2 balance N2 |
Compensation: | Barometric pressure and temperature | Connections: | 1/8″ compression tube fittings |
Controls: | Menu driven range selection, calibration and system functions | Display: | Graphical LCD 2.75” x 1.375”; resolution 0.01 PPM; displays real time ambient temperature and pressure |
Enclosure: | Painted aluminum NEMA 4X, 4”x9”x3″, 8 lbs. | Flow Sensitivity: | None between 0.5-5 SCFH, 1-2 SCFH recommended |
Linearity: | ±1% of full scale | Pressure: | Inlet – regulate to 5-30 psig, vent – atmospheric |
Power: | 18-24 VDC | Recovery Time: | 60 seconds in air to < 10 PPM in < 1 hour on N2purge |
Response Time: | 90% of final reading in 10 seconds | Sample System: | None |
Sensitivity: | < 0.5% of FS range | Sensor Model: | GPR-11-32 for inert gases; |
Sensor Life: | 32 months at 25ºC and 1 atm. | Signal Output: | 4-20mA Loop Powered |
Operating Range: | -10 ºC to 45ºC | Warranty: | 12 months analyzer; 12 months sensor |
Wetted Parts: | Stainless steel |
*At constant temperature and pressure
Optional Equipment | |||
XLT-11-24 | Sensor for gas mixtures containing CO >0.5% | ||
Sample System | Pressure regulator, flow meter, flow control valve | ||
Enclosure | Analyzer housed in NEMA 4 Enclosure |